Model Releases
Model Effect or Label Effect? Refined Annotations and a Human-Referenced Benchmark for Pulmonary Embolism Segmentation
arXiv:2608.24486v1 Announce Type: cross Abstract: Purpose: To quantify how evaluation annotations influence measured pulmonary embolism (PE) segmentation performance relative to model training changes
arXiv:2608.24486v1 Announce Type: cross Abstract: Purpose: To quantify how evaluation annotations influence measured pulmonary embolism (PE) segmentation performance relative to model training changes, and to establish a human-referenced framework. Materials and Methods: This retrospective study screened 166 voxel-annotated CT pulmonary angiography cases from CADPE (n=91), FUMPE (n=35), and READ (n=40); 149 were included. A primary rater annotated PE by protocol, and a senior thoracic radiologist reviewed and revised all segmentations. Three additional raters at three centers annotated a 15-case subset. The label effect was measured by evaluating two pretrained nnU-Net models (nnU-Net-A, nnU-Net-B) against original and refined annotations. The model effect was measured by comparing the same architecture trained on different dataset combinations with annotations fixed. The benchmark model (nnPE) was trained with leave-one-dataset-out and pooled five-fold cross-validation. Four metric categories were analyzed with case-paired Wilcoxon signed-rank tests, Benjamini-Hochberg correction, and bootstrap 95% CIs. Results: Changing only the annotation increased mean DSC by 0.143 (0.122-0.166) for nnU-Net-A and 0.188 (0.163-0.213) for nnU-Net-B (both P < .001), whereas changing training-dataset composition changed DSC by 0.028. The label effect exceeded the model effect on CADPE and FUMPE and was 0.045 on READ. Within-mask attenuation SD fell in all three datasets after re-annotation (all P < .001). nnPE reached DSC 0.72 +/- 0.22 on pooled cross-validation but scored below all four annotators across 52 paired comparisons (all corrected P < .05). Conclusion: Evaluation annotations affected measured PE segmentation performance at least as much as model training choices. A human-referenced evaluation framework is publicly available for future study.
Related
- CTSCAN: Evaluation Leakage in Chest CT Segmentation and a Reproducible Patient-Disjoint Benchmark
- Large Language Model-Assisted Cleaning of Report-Derived Labels in a Large-Scale Chest CT Dataset
- Data-Centric Benchmark for Label Noise Estimation and Ranking in Remote Sensing Binary Building Segmentation
- Trustworthy Medical Segmentation: Uncertainty-Aware U-Net Evaluation Under Clinical Image Degradation
Source: arXiv cs.CV | 2026-08-26